029-89301886

Flame Retardant Testing of Cables & Building Materials

Home > Product > Geotextiles & Building Testing Instruments > Flame Retardant Testing of Cables & Building Materials

YS-DYM-2 wire and cable smoke density test device

产品描述:

YS-DYM-2 wire and cable smoke density test device

  • 产品型号

  • 发布时间

    2026-03-18
  • 企业性质

  • 浏览次数

7×24在线咨询

专业客服在线解答,为您解决遇到的问题!

立即咨询

详细介绍

YS-DYM-2 wire and cable smoke density test device

【Scope of application】

The determination of smoke density is an important aspect of evaluating the combustion characteristics of cables or optical cables, which is related to the evacuation of personnel and the judgment of whether they can be close to extinguish the fire. This instrument is mainly used to determine the smoke concentration released by cables and optical cables when burned under specific conditions, and to verify the smoke density generated. In flame-burning or flameless combustion conditions, light transmittance is used as a way to compare different cables or fiber optic cables under specific conditions.

【Relevant Standards】

  • It complies with Part 1 "Test Device" and Part 2 "Test Procedures and Requirements" in GB/T17651.1~2 and IEC61034-1~2 "Determination of Smoke Density of Combustion of Cables or Optical Cables under Specific Conditions".

  • YS-DYM-2 wire and cable smoke density test device.png

[Scope of application]:
The determination of smoke density is an important aspect of evaluating the combustion characteristics of cables or optical cables, which is related to the evacuation of personnel and the judgment of whether they can be close to extinguish the fire. This instrument is mainly used to determine the smoke concentration released by cables and optical cables when burned under specific conditions, and to verify the smoke density generated. In flame-burning or flameless combustion conditions, light transmittance is used as a way to compare different cables or fiber optic cables under specific conditions.
[Meet the standard]:
 It complies with Part 1 "Test Device" and Part 2 "Test Procedures and Requirements" in GB/T17651.1~2 and IEC61034-1~2 "Determination of Smoke Density of Combustion of Cables or Optical Cables under Specific Conditions".
[Instrument features]: 
1. Dual operation mode, can be operated on the touch screen, or can be controlled on the computer, and the operation mode can be switched arbitrarily;(Computer and printer users bring their own, and the host computer software is issued with the device)
2. The framework is simple;
3. It has an autonomous ignition system, which is safer;
4. One-click operation, simpler;
5. Software independent development.
 【Technical Parameters】:
1. Combustion chamber: internal size: 3M ×3M× 3M a total of 27 cubic meters. It can be brick wall structure or steel plate structure, which is chosen by the customer.
2. Light measurement device: A. Imported quartz halogen lamp from the light source: nominal power 100W, nominal voltage: 12V, nominal light return: 2000-3000Lm  
B. Acceptor: silicon photocell, light transmittance 0% is no light passing, light transmittance 100% light is completely unobstructed.   
3. Standard ignition source: A. The ignition source is 1.0L alcohol (user-prepared)
B. Alcohol plate: stainless steel, bottom surface 210×110mm,
Top surface 240×140mm, height 80mm
4. Mixing of smoke: Use a desktop fan to distribute the smoke evenly in the combustion chamber.
5. Blank test: Burning alcohol lamp makes the temperature of the combustion chamber reach 25±5°C.
6. Temperature measurement device: 1.5M from the ground on the inner surface of the door,
A temperature sensor is installed 0.5 meters from the wall.
7. Includes a set of light transmittance measurement software, which can output curves and reports.
8. Power: 220V, 4KW. (should indicate the total power of the device)
9. (Smoke density) 0-924 six-speed automatic shift
10. Measurement range: 0.0001-100%;
11. Measurement accuracy: ±3%;
12. Working voltage: 200-240V 50Hz;
13. Ambient temperature: room temperature—40°C
14. Relative temperature: ≤85%;
15. Working environment: When the instrument is running, avoid direct light and no forced air flow.