029-89301886
【Scope of application】
It is used to test the horizontal water flow performance of the drainage plate (specimen).
【Relevant Standards】
JTJ/T257-1996, SL/T235-1999 and other standards.
【Instrument Usage】:
It is used to test the horizontal water flow performance of the drainage plate (specimen).
[Meet the standard]:
JTJ/T257-1996, SL/T235-1999 and other standards.
【Technical Parameters】:
1. Maximum size of the tested specimen: 400mm×100mm×10mm (L×W×H);
2. Water head difference: 200mm, hydraulic gradient is 0.5;
3. Maximum pressurization: 350Kpa;
4. Overall dimensions: 820mm×230mm×580mm (L×W×H);
5. Weight: 50Kg;