YS-382B Diaper Permeability Tester
产品型号
YS-382B发布时间
2020-07-21企业性质
生产厂家浏览次数
相关产品
RELATED PRODUCTS
YG026T Electronic Fa
型号:YG026T
YS-382B Diaper Perme
型号:YS-382B
详细介绍
【Scope of application】
Diaper absorption performance tester is used to determine the absorption speed, re-osmosis performance and permeability of diapers and other products.
【Relevant Standards】
GB/T28004.1, GB/T28004.2-2021, etc.
【Scope of application】:
Diaper absorption performance tester is used to determine the absorption speed, re-osmosis performance and permeability of diapers and other products.
[Meet the standard]:
GB/T28004.1, GB/T28004.2-2021, etc.
[Instrument features]:
1. The test solution for testing adopts peristaltic pump control dosing method to ensure the stability and repeatability of dosing, and the dosing accuracy can reach ±1%.
2. The heating method of the test solution (normal saline) adopts the water bath heating method, which will not have any impact on the performance of the test solution.
3. Children's diaper test sample fixture: 3 U-shaped bases, 3 specimen holders, 3 standard liquid filling modules, and 3 standard pressurization modules.
4. Adult diaper specimen fixture: 1 U-shaped base, 2 standard dosing modules, and 2 standard pressurization modules.
5. All specimen fixtures are made of high-permeability materials for precision machining, which is convenient for real-time observation and measurement process, corrosion resistance, and durability.
6. The whole machine adopts desktop structure design, which is stable in operation and more convenient to move and install.
7. The main control adopts Mitsubishi PLC control, which is precise and stable.
8. Kunlun general touch screen is used for control and display.
【Technical Parameters】:
1. Children's diaper test parameter size
1.1. Parameters of U-shaped specimen base:
B1: L:125±1mm W:122±1mm
B2: L:136±1mm W:135±1mm
B3: L:154±1mm W:152±1mm
1.2. Standard dosing module parameters:
M1: L:100±1mm W:80±1mm
M2: L:108±1mm W:85±1mm
M3: L:125±1mm W:95±1mm
1.3. Standard test pressurization module:
Y1: L:100±1mm W:80±1mm
Y2: L:108±1mm W:85±1mm
Y3: L:125±1mm W:95±1mm
2. Adult diaper test parameter size
2.1. Parameters of U-shaped specimen base:
L:319±1mm W:200±1mm
2.2. Standard dosing module parameters:
M1: L:170±1mm W:70±1mm
M2: L:170±1mm W:95±1mm
2.3. Standard test pressurization module:
Y1: L:170±1mm W:70±1mm
Y2: L:170±1mm W:95±1mm
3. Pressurized pressure: 2.0±0.2 KPa, 4.0±0.2 KPa
4. Dosing flow rate: 480±5 ml/min (children), 750±5ml/min (adults)
5. Timing range: 0.00 ~ 9999.99 s
6. Heating range of test solution: room temperature +5°C~50°C
7. Power supply: AC220V, 200W, 50Hz
8. Size L×W×H: 480mm×460mm×1000mm
[Configuration list]:
1. 1 main unit
2. 1 water bath pot
3. 1 set of baby diaper test fixture (U-shaped base B1, B2, B3, sample holder T1, T2, T3, standard test dosing module M1, M2, M3, standard test pressurization module Y1, Y2, Y3)
4. 1 set of adult diaper test fixture (U-shaped base B, standard test dosing module M1, M2, standard test pressurization module Y1, Y2)
5. 1 product certificate
6. 1 copy of the product instruction manual
7. 1 delivery note
8. 1 acceptance form
9. 1 copy of the product album
10. One hundredth electronic balance 1 set