029-89301886

Flame Retardant Testing of Cables & Building Materials

Home > Product > Geotextiles & Building Testing Instruments > Flame Retardant Testing of Cables & Building Materials

YS-GJL-3 Building Component Fire Resistance Test Horizontal Furnace

产品描述:

YS-GJL-3 Building Component Fire Resistance Test Horizontal Furnace

  • 产品型号

  • 发布时间

    2026-03-18
  • 企业性质

  • 浏览次数

7×24在线咨询

专业客服在线解答,为您解决遇到的问题!

立即咨询

详细介绍

YS-GJL-3 Building Component Fire Resistance Test Horizontal Furnace

【Scope of application】

The thermal insulation efficiency test of steel structure fireproof coatings is a new test item added to the national standard GB14907 "Steel Structure Fireproof Coatings" in the 2018 version of the update, which is not in the old version of the standard in 2002. In GB14907-2018, the deviation of thermal insulation efficiency of indoor/outdoor steel structure fireproof coatings is ±15%. Introduction to the thermal insulation efficiency and fire resistance limit test furnace of steel structure fireproof coating: The thermal insulation efficiency and fire resistance limit test furnace of steel structure fireproof coating is a special instrument for the fire resistance test of steel structure fireproof coatings developed according to the technical indicators specified in the national standard GB14907-2018 "Steel Structure Fireproof Coatings", GB/T9978-2008 Articles 4 and 5 of Articles 5.1 and 5.2. The thermal insulation efficiency and fire resistance limit test furnace of steel structure fireproof coating is directly controlled by touch screen, eliminating the tedious connection to computer installation software, and the overall test process is fully automatic, easy to operate and maintain, and the temperature error is smaller than the national standard.

【Relevant Standards】

  • Design standard: GB14907-2018 "Fireproof coatings for steel structures" GB/T9978-2008

  • YS-GJL-3 Building Component Fire Resistance Test Horizontal Furnace.png

Scope of application
  The thermal insulation efficiency test of steel structure fireproof coatings is a new test item added to the national standard GB14907 "Steel Structure Fireproof Coatings" in the 2018 version of the update, which is not in the old version of the standard in 2002. In GB14907-2018, the deviation of thermal insulation efficiency of indoor/outdoor steel structure fireproof coatings is ±15%.
Introduction to the thermal insulation efficiency and fire resistance limit test furnace of steel structure fireproof coatings:
   The thermal insulation efficiency and fire resistance limit test furnace of steel structure fireproof coatings is a special instrument for the fire resistance test of steel structure fireproof coatings developed according to the technical indicators specified in the national standard GB14907-2018 "Steel Structure Fireproof Coatings" and GB/T9978-2008 Articles 4 and 5 of Articles 5.1 and 5.
 The thermal insulation efficiency and fire resistance limit test furnace of steel structure fireproof coating is directly controlled by touch screen, eliminating the tedious connection to computer installation software, and the overall test process is fully automatic, easy to operate and maintain, and the temperature error is smaller than the national standard.
[Applicable Standards]:
Design standard: GB14907-2018 "Fireproof coatings for steel structures"
GB/T9978-2008
[Instrument features]:
1. Touch screen/computer dual control, can realize wireless connection, one computer can control multiple instruments at the same time, and one instrument can also be controlled by multiple computers at the same time
2. Automatic rejection of faulty thermocouple function
3. The overall process of the test is fully automated
4. Automatically draw the temperature curve of the test  
5. Automatically follow the pressure curve
6. Automatic heat dissipation function at the end of the test
7. Anti-false power off mode, avoid the damage caused by forced power off to the equipment
8. The fire will be automatically ignited during the test
9. Automatically stop the test when the set temperature is reached
10. Automatic exhaust air cooling after the test
11. More than 100 sets of data can be stored
12. The temperature error is lower than the national standard
【Technical Parameters】:
1. Working voltage: AC 220V±10% 50Hz; Power consumption: 3KW
2. Furnace pressure measurement range: 0-100Pa Furnace pressure control: 20±3Pa
3. Air flow: 0-50m3/min Measurement accuracy: ≤±0.5 m3/min
4. Fuel: No. 0 or -10 diesel
5. Test temperature: The program heats up for 60min at room temperature-925°C
             120min room temperature - 1050°C
             180min room temperature - 1115°C
             240min room temperature - 1150°C
             300min room temperature - 1180°C
             360min room temperature - 1210°C
6. Accuracy of instruments and equipment
Number of thermocouples in the furnace: 4 exact
Number of backfire temperature thermocouples: 2 pcs
Specimen backfire temperature: ±4°C
You can choose whether the backfire temperature is controlled by the average value or separately
7. Temperature measurement sensor: armored nickel-chromium-nickel-silicon K-value thermocouple Accuracy level: Class II
8. Heating method: automatic spray heater
9. Automatic exhaust air cooling at the end of the test
10. Can store 100 sets of data
10. Timing range: 0-360min Timing accuracy: <±2s
11. Specimen size: 500*500*6mm
12. Instrument dimensions: 1.6 meters*1.6 meters*1.6 meters  